Energy Storage Unit
Example of 100MW/400MWh Energy Storage System Layout Diagram
| Model | G50 | G100 | G250 |
| Rated Power | 50MW | 100MW | 250MW |
| Maximum Capacity | 200MWh~600MWh | 400MWh~1.2GWh | 1.2GWh~3GWh |
| Operating Voltage (AC) | 35kV | 35kV | 35kV |
| Operating Voltage (AC) | 824.8A | 2 × 824.8A | 5 × 824.8A |
| Rated Power | 50Hz | ||
| Footprint (mm) | 10000㎡ | 20000㎡ | 40000㎡ |
| DC Efficiency | ≥80% | ||||
| AC Efficiency | ≥70% | ||||
| Lifetime | >15000 times, DOD Depth 100%, Calendar fife >25 years | ||||
| Reaction Rate | ≤200ms | ||||
| Communication Interface | RJ45/RS485 | ||||
| Protection Class | IP30/IP54 | ||||
| Meet the Standard | GB/T 32509-2016 General specification for vanadium flow battery、GB/T 34866-2017 Vanadium flow battery - Safety requirements | ||||
| Ambient Temperature | -45℃~55℃ | ||||
| Relative Humidity | 5-95% | ||||
| Operating Altitude | <2000m,customizable for higher altitudes | ||||
| Protection Functions | Overvoltage and undervoltage protection, over-current protection, phase sequence fault protection, insulation monitoring | ||||
| Cooling method | Liquid cooling + air cooling | ||||
| Transportation method | Suitable for road transportation | ||||