Box-type K1 Series
Expansion Example of Box-type K1 Series
Model | K50 | K100 | K125 |
Rated Power | 50kW | 100kW | 125kW |
Maximum Capacity | 200kWh | 400kWh | 500kWh |
Operating Voltage (AC) | 202~317V | 403~633V | 267~422V |
Operating Voltage (AC) | 248A | 248A | 465A |
Length(mm) | 7500mm | 8500mm | 10500mm |
Width(mm) | 3000mm | 3500mm | 3500mm |
Height(mm) | 2900mm | 3300mm | 3200mm |
Weight (excluding electrolyte) | 10T | 13T | 15T |
DC Efficiency | ≥80% | ≥80% | ≥80% |
AC Efficiency | ≥65%(meeting international requirements) | ||
Lifetime | >15000 times, DOD Depth 100%, Calendar fife >25 years | ||
Reaction Rate | ≤200ms |
Communication Interface | RJ45 / RS485 |
Protection Class | IP30 / IP54 |
Meet the Standard | GB/T 32509-2016 General specification for vanadium flow battery、GB/T 34866-2017 Vanadium flow battery - Safety requirements |
Ambient Temperature | -45℃~55℃ | ||
Relative Humidity | 5~95% | ||
Operating Altitude | <2000m,customizable for higher altitudes |
Protection Functions | Overvoltage and undervoltage protection, over-current protection, phase sequence fault protection, insulation monitoring |
Cooling method | Liquid cooling + air cooling | ||||
Package | Prefabricated container | ||||
Transportation method | Suitable for road transportation and ship transportation |