Battery Module
Electrical Parameters
Rated Power | 250kW | 334KW | 420KW | 500KW | 672kW |
Operating Voltage (DC) | 135~211V | 267~422V | 135~211V | 202~316V | 267~422V |
Operating Voltage (DC) | ≤1860A | ≤1243A | ≤3125A | ≤2480A | ≤2500A |
Length | 6058mm | 6058mm | 6058mm | 6058mm | 6058mm |
Width | 2438mm | 2638mm | 2638mm | 2638mm | 2638mm |
Height | 2591mm | 2591mm | 3500mm | 3500mm | 3500mm |
Weight | 10T | 10T | 11T | 12T | 15T |
DC Efficiency | ≥80% | |
Lifetime | >15000 times, DOD Depth 100%, Calendar fife >25 years | |
Reaction Rate | ≤200mS |
Communication Interface | RJ45/RS485 |
Protection Class | IP30/IP54 |
Meet the Standard | GB/T 32509-2016 General specification for vanadium flow battery,GB/T 34866-2017 Vanadium flow battery - Safety requirements |
Ambient Temperature | -45℃~55℃ | |
Relative Humidity | 5~95% | |
Operating Altitude | <2000m, customizable for higher altitudes |
Protection Functions | Overvoltage and undervoltage protection, over-current protection, phase sequence fault protection, insulation monitoring |
Cooling method | Liquid cooling + air cooling | |
Package | Prefabricated container | |
Transportation method | Suitable for road transportation |